RIC at Ankara, Turkey (Region VI)
|
(Information on this webpage
is based on the lastest report from the RIC.
Please refer to the RIC's website for the latest information.) |
|
General Information |
Address:
Turkish State Meteorological Service,
Kalaba Mahallesi Kütükçüalibey Caddesi No:4,
06120
Ankara,
Turkey |
Website:
https://mgm.gov.tr/eng/calibration-center.aspx |
Contact person:
Zafer Turgay
DAG |
Email:
ztdag@mgm.gov.tr |
Tel:
+90 312 302 2209
|
Fax:
+90 312 361 5356
|
Calibration capabilities: Temperature, Relative Humidity, Atmospheric Pressure, Wind, Precipitation, Other |
|
Specific Information on instrument calibration capabilities |
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Resistance thermometer |
0.01 °C |
Triple Point of Water Cell YUKAL-L1 |
8 mK |
14 April 2017 |
YUKAL
(Yeditepe University Calibration Center) |
Resistance thermometer |
-40 to 50 °C |
SPRT Isotech 909Q, Fluid calibration bath FLUKE 7341, Fluid calibration bath FLUKE 7381 |
40 mK |
4 May 2017 |
TUBITAK-UME (National Metrology Institute)
|
Resistance thermometer |
-40 to 50 °C |
PRT Hartscientific 5615-1521, Climate chamber V ÖTSCH VC³ 7018 |
130 mK |
21 December 2017 |
TSMS
(Turkish State Meteorological Service) Calibration Center |
Fully immerged liquid in glass thermometer |
-40 to 50 °C |
SPRT Isotech 909Q, Fluid calibration bath FLUKE 7341, Fluid calibration bath FLUKE 7381 |
60 mK |
4 May 2017 |
TUBITAK-UME (National Metrology Institute) |
Thermometer with display |
-40 to 50 °C |
SPRT Isotech 909Q, Fluid calibration bath FLUKE 7341, Fluid calibration bath FLUKE 7381 |
50 mK |
4 May 2017 |
TUBITAK-UME (National Metrology Institute) |
Thermometer with display |
-40 to 50 °C |
PRT Hartscientific 5615-1521, Climate chamber V ÖTSCH VC³ 7018 |
130 mK |
21 December 2017 |
TSMS
(Turkish State Meteorological Service) Calibration Center |
|
Status of accreditation (date of the latest accreditation): 7 November 2018 |
Link to the Certificate of Accreditation |
Accreditation body: Turkish Accreditation Agency (TÜRKAK) |
|
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Relative humidity measuring instruments |
10 to 80 %RH |
Thunder Scientific 2500 Humidity Generator (at the fixed temperature point of (23±1) °C) |
1.2 %RH |
21 November 2017 |
TUBITAK-UME (National Metrology Institute)
|
Relative humidity measuring instruments |
81 to 95 %RH |
Thunder Scientific 2500 Humidity Generator (at the fixed temperature point of (23±1) °C) |
2.0 %RH |
21 November 2017 |
TUBITAK-UME (National Metrology Institute) |
Relative humidity measuring instruments |
10 to 80 %RH |
Vaisala HMP76 (M170), Climate chamber VÖTSCH VC³ 7018 (at the fixed temperature point of (23±1) °C) |
2.5 %RH |
21 November 2017 |
TSMS
(Turkish State Meteorological Service) Calibration Center |
|
Status of accreditation (date of the latest accreditation): 7 November 2018 |
Link to the Certificate of Accreditation |
Accreditation body: Turkish Accreditation Agency (TÜRKAK) |
|
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Absolute pressure
Barometers |
750 to 1050 hPa |
Quartz barometer Paroscientific 765-16B, Pressure chamber Elite PCS-600 |
0.12 hPa |
28 September 2018 |
TUBITAK-UME (National Metrology Institute)
|
Absolute pressure
Barometers |
750 to 1050 hPa |
Quartz barometer Paroscientific 765-16B, Pressure generator DHI type PPC4 |
0.08 hPa |
28 September 2018 |
TUBITAK-UME (National Metrology Institute) |
|
Status of accreditation (date of the latest accreditation): 7 November 2018 |
Link to the Certificate of Accreditation |
Accreditation body: Turkish Accreditation Agency (TÜRKAK) |
|
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Anemometer
(Pitot tube, propeller, thermal, cups, ultrasonic etc.) |
1.0 to 3.0 m/s |
Pitot Tube Micromanometer Furness Control FCO510 / B675, in Wind tunnel
|
3.0 % |
28 May 2018 |
TUBITAK-UME (National Metrology Institute) |
Anemometer
(Pitot tube, propeller, thermal, cups, ultrasonic etc.) |
3.0 to 35.0 m/s |
Pitot Tube Micromanometer Furness Control FCO510 / B675, in Wind tunnel |
2.0 % |
28 May 2018 |
TUBITAK-UME (National Metrology Institute) |
|
Status of accreditation (date of the latest accreditation): 7 November 2018 |
Link to the Certificate of Accreditation |
Accreditation body: Turkish Accreditation Agency (TÜRKAK) |
|
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Rain gauge (Tipping bucket, weighting, etc.) |
10 to 300 mm/h |
Mass set Baykon F1 class, Mettler Toledo XP4002SDR
Electronics balance, with Watson Marlow 520Du peristaltic pump |
1.0 % |
18 June 2014
21 May 2018 |
TUBITAK-UME (National Metrology Institute)
TSE (Turkish Standards Institution) |
|
Status of accreditation (date of latest accreditation):
This Laboratory is not accredited, but it also works in accordance with TS EN ISO/IEC 17025 Standards.
|
Link to the scope of non-accredited methods |
Accreditation body: |
|
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Global Radiation
(Pyranometer) |
0 to 700 W/m2 |
Kipp&Zonen CMP22 pyranometer under constant light intensity |
1,0 % |
1 June 2018 |
Kipp&Zonen |
Wind direction measuring instruments (Wind vane) |
0 to 360° |
Electronics Teodolite SSMI DE2 |
4° |
21 November 2018 |
TUBITAK-UME (National Metrology Institute)
|
Electrical Calibration Laboratory Current(DC,AC), Voltage (DC,AC), Resistance (DC), Frequency (Hz) |
at the scope |
Electrical calibrator FLUKE 5520A, Digital Multimeter 8½ digit KEITHLEY 2002 |
at the scope |
21 September 2017
22 November 2017 |
TSE (Turkish Standards Institution)
|
|
Status of accreditation (date of latest accreditation):
These Laboratories are not accredited, but they also work in accordance with TS EN ISO/IEC 17025 Standards.
|
Link to the scope of non-accredited methods |
Accreditation body: |
|