RIC at Nairobi, Kenya (Region I) |
(Information on this webpage is based on the latest report from the RIC.
Please refer to the RIC's website for the latest information.)
|
|
General Information |
Address: Kenya Meteorological Department, P.O. Box 30259, Ngong Road, 00100 Nairobi, Kenya |
Website: http://www.meteo.go.ke/ |
Contact person: Richard MUCHIRA |
Email: director@meteo.go.ke; er_gitari@yahoo.com,
jtnjoroge@gmail.com
|
Tel: +254 20 386 78 80; + 254 72 272 22 85 405,
+254 72 299 19 01
|
Fax:
+254 20 387 69 55 |
Calibration capabilities: Temperature, Relative Humidity, Atmospheric Pressure, Precipitation, Solar Radiation |
|
Specific Information on instrument calibration capabilities |
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Thermohygrograph |
0 to 40 °C |
Climate Test Chamber
Typoe 3523/17
|
|
|
|
Liquid in Glass Thermometers
|
-10 to 51 °C
|
Stirred Liquid Oil Bath |
|
|
|
PT 100
|
0 to 100 °C |
F252/F252 Precision Thermometer
|
|
|
|
|
Status of accreditation (date of the latest accreditation): |
Link to the accreditation certificate: |
Accreditation body: |
|
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Thermohygrograph |
10 to 95 % |
Capacitive Humidity Sensor in Climate Chamber
|
|
|
|
|
5 to 95 % |
Hygrogen |
|
|
|
|
Status of accreditation (date of the latest accreditation): |
Link to the accreditation certificate: |
Accreditation body: |
|
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Precision/Aneroid
Digital Barometer |
500 to 1000 hPa |
Vaisala PTB Barometer
Pressure Chamber
|
|
|
|
|
Status of accreditation (date of the latest accreditation): |
Link to the accreditation certificate: |
Accreditation body: |
|
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Tipping Bucket |
100/0.1/10 mm
50/0.2/10 mm | Precipitation Sensor Calibrator |
|
|
|
|
Status of accreditation (date of the latest accreditation): |
Link to the accreditation certificate: |
Accreditation body: |
|
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Pyranometer |
50 to 120 W/m2, when fully cloudy;
120 - 500 W/m2, when cloudy; 500 to 1000 W/m2, when clear and sunny |
Two reference pyranometers for calibration of global radiation |
|
|
|
|
Status of accreditation (date of the latest accreditation): |
Link to the accreditation certificate: |
Accreditation body: |
|