RIC at Beijing, China (Region II)
|
(Information on this webpage
is based on the latest report from the RIC.
Please refer to the RIC's website for the latest information.) |
|
General Information |
Address:
Meteorological Observation Centre of China Meteorological Administration,
No. 46, Zhongguancun Nandajie,
100081
Beijing,
China |
Website:
|
Contact person:
Xuejing
NAN |
Email:
576809156@qq.com |
Tel:
8610-68400493
|
Fax:
8610-68409767
|
Calibration capabilities: Temperature, Relative Humidity, Atmospheric Pressure, Wind, Precipitation, Solar Radiation |
|
Specific Information on instrument calibration capabilities |
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Standard Mercury-in-Glass Thermometers;
Pt Resistance Thermometers
|
-60 to 80 °C |
First-class Standard Pt Resistance Thermometer |
50 mK
|
29 March 2018 |
National Institute of Metrology, China |
|
Status of accreditation (date of the latest accreditation): 27 June 2018 |
Link to the accreditation certificate: Registration No. L11135 |
Accreditation body:
China National Accreditation Service for Conformity Assessment (CNAS) |
|
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Standard Ventilation Psychrometers;
Hygrometers |
5 to 98 %RH
|
Precision Dew-point Hygrometer
|
0.4 to 1.5 %RH
|
12 April 2018 |
National Institute of Metrology, China |
|
Status of accreditation (date of the latest accreditation): 27 June 2018 |
Link to the accreditation certificate: Registration No. L11135 |
Accreditation body: China National Accreditation Service for Conformity Assessment (CNAS) |
|
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Digital barometers |
90 to 3500 hPa |
Gas Piston Pressure Gauge
|
1 to 4 Pa
(100 to 1200 hPa) |
26 May 2017 |
National Institute of Metrology, China |
|
Status of accreditation (date of the latest accreditation): 27 June 2018 |
Link to the accreditation certificate: Registration No. L11135 |
Accreditation body: China National Accreditation Service for Conformity Assessment (CNAS) |
|
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Portable 3-cup
anemometers |
0.2 to 70 m/s |
Pilot tube
|
0.07 m/s
(2 to 30 m/s) |
7 April 2014 |
National Institute of Metrology, China |
Wind direction and wind speed sensor for automatic weather station |
0.08 m/s
(2 to 40 m/s)
0.08 to 0.18 m/s
(40 to 60 m/s) |
Magnetoelectricity wind speed sensor for wind farm |
0.07 m/s
(3 to 30 m/s) |
Hot bulb anemometer |
0.07 to 0.25 m/s
(0.5 to 2 m/s)
0.07 m/s
(2 to 30 m/s) |
|
Status of accreditation (date of the latest accreditation): 27 June 2018 |
Link to the accreditation certificate: Registration No. L11135 |
Accreditation body: China National Accreditation Service for Conformity Assessment (CNAS) |
|
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Raingauges, Measuring cylinders |
0 to 942.48 mL |
Standard Capacity Measurement (glass) |
MPE:
± (0.031 to 0.314) mL |
October 2016 |
National Institute of Metrology, China |
|
Status of accreditation (date of the latest accreditation): |
Link to the accreditation certificate |
Accreditation body: |
|
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Pyrheliometer |
5 to 15
μV/(W/m²) |
Cavity Radiometer |
0.6 %
|
October 2015 |
PMOD-WRC Davos, Switzerland |
Pyranometer |
5 to 25 μV/(W/m²) |
Secondary Standard Pyranometer |
1.6 % |
November 2018 |
National Center for Meteorological Metrology,China |
|
Status of accreditation (date of the latest accreditation): 27 June 2018 |
Link to the accreditation certificate: Registration No. L11135 |
Accreditation body:
China National Accreditation Service for Conformity Assessment (CNAS) |
|