RIC at Algiers, Algeria (Region I)
|
(Information on this webpage
is based on the latest report from the RIC.
Please refer to the RIC's website for the latest information.) |
|
General Information |
Address:
Office National de la Météorologie,
1, Av. Med Khemisti,
BP 153 16033
Algiers, Algeria |
Website:
www.meteo.dz |
Contact person:
Kheireddine
AKLIL |
Email:
k.aklil@meteo.dz |
Tel:
+213 21 50 69 10 / +213 21 50 79 43 |
Fax:
+213 21 50 88 49 / +213 21 50 89 50 |
Calibration capabilities: Temperature, Relative Humidity, Atmospheric Pressure, Solar Radiation |
|
Specific Information on instrument calibration capabilities |
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Platinum resistance thermometers |
-40 to 125 °C |
Primary standard SPRT 25 Ω (ASL CTP5000) liquid bath with equalizing block (Isotech 796L 470 mm end 8.5 L, resistance bridge (CPT5000 and CTH7000) |
10 mK |
September 2017 |
Laboratory AIRMETROLOGY
(DKD accreditation No. B12249)
|
Platinum resistance thermometers |
-40 to 125 °C |
Primary standard SPRT 100 Ω (ASL CTR3000) liquid bath with equalizing block (Isotech 796L 470 mm end 8.5 L, resistance bridge (CPR3000 and CTH7000) |
10 mK |
September 2017 |
Laboratory AIRMETROLOGY
(DKD accreditation No. B12249) |
Alcohol/Mercury thermometers |
-20 to 60 °C |
Precision thermometry |
0.2 °C |
March 2018 |
Laboratory AIRMETROLOGY
(DKD accreditation)
|
|
Status of accreditation (date of the latest accreditation): |
Link to the accreditation certificate |
Accreditation body: |
|
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
|
10 to 98 %RH |
Dew-point Mirror (Optidew et Optidew vision) |
1.6 %RH
|
March 2018 |
Laboratory AIRMETROLOGY
(UKAS accreditation No. 02830) |
|
Hygrogen generator (Hygro Cal100) |
Hygrographs |
Climatic chamber |
|
Status of accreditation (date of the latest accreditation): |
Link to the accreditation certificate |
Accreditation body: |
|
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Digital barometers |
0 to 1100 hPa
|
Barometer CPC6000 IS50; Nitrogen Generator CPC600 |
(0.02 mbar + 1.3x10-5 P) |
October 2018 |
Laboratory AIRMETROLOGY
(COFRAC accreditation No. 51058) |
Digital barometers |
0 to 1100 hPa |
Barometer CPG2500 |
(0.02 mbar + 1.3x10-5 P) |
October 2018 |
Laboratory AIRMETROLOGY
(COFRAC accreditation No. 51056) |
Digital barometers |
500 to 1100 hPa
|
Barometer reference P501 |
(0.03 mbar + 2x10-5 P) |
January 2019 |
Laboratory AIRMETROLOGY
(COFRAC) |
|
Status of accreditation (date of the latest accreditation): |
Link to the accreditation certificate |
Accreditation body: |
|
|
Instrument Undergoing Calibration |
Calibration Range |
Reference standard, Equipment |
Calibration and Measurement Capability (CMC)* |
Traceability of Reference equipment |
Last standard calibration date |
Calibration body |
Pyranometer
pyrheliometer |
< 5 % |
AHF pyrheliometer
N°29225
Installed in Tamanrasset |
0.2 to 0.3 % |
September 2010
Reference calibration every five years in Davos |
Comparaison with the global reference
Davos |
|
Status of accreditation (date of the latest accreditation): |
Link to the accreditation certificate |
Accreditation body: |
|